ZENES · Technology. Engineering. Project management.
Used Machinery+90 555 334 19 77
ZENES /

Foundry Shakeout Grid: Capacity, Drive Power, Selection

How to size a foundry shakeout grid: deck load, deck size, vibrator motor power, green sand vs no-bake, dust and noise, plus a checklist for buying used.

A shakeout grid is a vibrating deck that breaks up the mould after casting and separates the sand from the casting and the flask. Three things size it: the heaviest load landing on the deck (sand, flask and casting together), moulds per hour, and the type of sand. With green sand the main question is load capacity; with no-bake sand it is whether the grid can break the mould without leaving lumps.

How it works

The deck sits on coil springs or rubber mounts. Two vibrator motors bolted to the side turn in opposite directions and give the deck a linear vibration, typically 16–25 Hz (1,000–1,500 rpm motors) with 3–8 mm amplitude. Sand drops through the grid onto a belt or vibrating trough below; the casting and flask stay on top and are lifted off by crane or manipulator.

Types of shakeout

Stand-alone grid: for flask work moulded by hand or crane. The mould is set on the deck, shaken for a few minutes, then the casting and flask come off. The most common and simplest option.

Punch-out plus grid: on automatic flask lines a hydraulic ram pushes the mould out of the flask. The empty flask returns to the line and the sand and casting drop onto a grid or vibrating conveyor.

Vibrating conveyor shakeout: on flaskless lines the mould leaves the end of the cooling line into a vibrating trough that breaks it and carries the casting forward.

Rotary drum: shakeout, casting cooling and sand homogenizing in one unit. On high-volume green sand lines it saves floor space and labour. Check impact risk first if you pour thin-walled or brittle parts.

Lump breaker for no-bake sand: furan or alkaline phenolic moulds do not fall apart like green sand. Without a lump breaker after the grid, large lumps go straight into the reclamation plant.

Typical capacity and drive power

  • 1–3 t — Deck size (typical): 1.2 × 1.5 m – 1.5 × 2 m; Vibrator motors (typical): 2 × 1.5 – 2 × 4 kW
  • 3–10 t — Deck size (typical): 2 × 2.5 m – 2.5 × 3.5 m; Vibrator motors (typical): 2 × 4 – 2 × 10 kW
  • 10–30 t — Deck size (typical): 3 × 4 m – 4 × 6 m; Vibrator motors (typical): 2 × 10 – 2 × 25 kW

Use the table for a first estimate; the maker sets the final motor size from the total vibrating mass. Make the deck 150–250 mm larger than your biggest flask on every side.

What to look at when choosing

  1. Heaviest load: sand, flask and casting together. A load dropped by crane is an impact load, so leave margin above the rated capacity.
  2. Moulds per hour: shakeout takes typically 30–90 seconds for green sand and longer for no-bake. If one grid cannot keep up with the line, you need a second grid or a drum.
  3. Sand type: green sand breaks easily; no-bake needs more power and a lump breaker.
  4. Shakeout temperature: heavy sections shaken out too early can distort, and iron castings can come out harder. The belt underneath must handle hot sand.
  5. Dust and noise: plan an extraction hood or an enclosure over the grid. Noise can go above 100 dB.
  6. Foundation: weak spring isolation sends vibration into the building. Get the foundation designed before installation.
  7. Sand handling below: trough, belt and elevator capacity must match the sand flow off the grid.

Typical failures we see in the field

Motor bolts work loose and fatigue cracks start around the motor mounting. Springs break or rubber mounts harden, and the vibration goes out of balance. Grid bars wear and the openings widen until small castings fall through with the sand. Vibrator motor bearings wear out faster than other motors in hot, dusty conditions.

Checklist for a used shakeout grid

  • Frame: cracks or repair welds, especially at the motor mounting and corners.
  • Grid bars: wear, bending, and whether they can be replaced.
  • Springs or mounts: broken, settled or mismatched springs.
  • Vibrator motors: make, power, bearing noise, eccentric weight setting.
  • Watch it run: equal amplitude at all four corners, no rocking.
  • Scope: are the hood, the trough or belt below and the control panel included?
  • Size: does it suit your largest flask and heaviest load?

FAQ

Shakeout grid or rotary drum? A grid for flask work and a wide part mix. A drum for high-volume green sand lines with no room for a cooling line and parts that can take some impact.

How is vibrator motor power chosen? The maker works from the total vibrating mass (deck plus load) and the acceleration needed. What you need to give them is the heaviest load, the flask size and the sand type.

Do I need a lump breaker with no-bake sand? If you reclaim the sand, yes. Large lumps passing the grid overload the reclamation unit and lower the recovery rate.

When should the mould be shaken out? Typically once the casting has cooled to around 400–700 °C. Heavy sections need longer; the part and the alloy set the exact time.

Related listings and guides

Used: USED-1955 FTL shake-out and sand separation system. Related guides: Casting cooling conveyor, Sand conveying in foundries, Resin sand reclamation, Foundry dust collectors, Flaskless moulding machines, Foundry sand coolers.

How ZENES helps

We size the shakeout together with the sand return and dust extraction under and around it, not as a single machine. For new grids we collect quotes from makers on the same scope; for used grids we test the machine running on site before you buy. Send your largest flask size, mould weight and moulds per hour and we will suggest the right grid.

WhatsApp ↗