Foundry Dust Collector: Airflow, Bags and Sizing

How to size a pulse-jet baghouse for a foundry: typical airflow for melting, shakeout and shot blasting, fan power, filter media and a used-unit checklist.

Most foundries use a pulse-jet baghouse for dust collection. You size it by adding up the airflow at every extraction point, then choosing enough filter area for that airflow, typically 1 to 1.5 m³ of air per minute for each square metre of bag. Undersized airflow is the most common reason foundry dust systems disappoint.

Where the dust comes from

  • Melting: induction furnaces give off fume and fine metal oxide during charging and tapping. Fine, hot and often carrying sparks. Cupola off-gas is a separate problem and usually needs a wet scrubber or a dedicated dry system.
  • Shakeout: hot sand, steam and bentonite dust all at once. This is usually the single biggest airflow in the plant.
  • Sand plant: sand cooler, screens, bucket elevators and belt transfer points. A sand cooler alone is a large load; an 80 t/h cooler pulls around 15,000 m³/h.
  • Cleaning room: worn shot and sand dust from blast machines, metal and abrasive dust from grinding.
  • Core shop: resin sand processes add odour and gas, which a dust filter alone will not handle.

Typical airflow ranges

These are rough field ranges. Real values depend on hood design, how enclosed the source is and part size, so every point is calculated separately in a project.

  • Induction furnace, 1-3 t, lid hood — Typical airflow (m³/h): 8,000 - 25,000
  • Shakeout grid, enclosed — Typical airflow (m³/h): 15,000 - 50,000
  • Sand cooler, 80-120 t/h — Typical airflow (m³/h): 15,000 - 18,000
  • Tumble blast machine — Typical airflow (m³/h): 2,500 - 8,000
  • Hanger blast machine — Typical airflow (m³/h): 6,000 - 20,000
  • Grinding station (each) — Typical airflow (m³/h): 1,500 - 3,000

For fan power, a working rule: every 10,000 m³/h at 2,500-3,000 Pa system pressure needs an 11-15 kW motor. Long ducts with many bends push that up.

Filter types

Pulse-jet baghouse: the default for foundry dust. Bags are cleaned on line by compressed air pulses at 5-7 bar. If the compressor was not sized for it, the filter starts to blind within months.

Cartridge filter: compact, fine for small airflows on blasting and grinding. It blinds quickly on damp or sticky dust, so it is rarely used on shakeout.

Cyclone pre-separator: takes out coarse sand and sparks before the bags. Adds years to bag life on blast and shakeout lines.

Wet scrubber: for cupola gas and for combustible metal dust such as aluminium or magnesium. You then have sludge to deal with.

How to choose

  1. Airflow: list each point, add them up, keep 10-15% spare, and allow for machines you will add later.
  2. Air-to-cloth ratio: around 1-1.2 m/min for shakeout and furnace fume, 1.2-1.5 m/min for blasting. A higher ratio makes the first quote cheaper and the bags shorter-lived.
  3. Media: polyester is good to about 130 °C. Hot furnace fume needs aramid or another high-temperature felt. Damp sand calls for an oil and water repellent finish.
  4. Spark arrestor: on melting and grinding lines, skip it and you will have a bag fire sooner or later.
  5. Explosion protection: aluminium or magnesium dust means ATEX design, vent panels and proper earthing.
  6. Dust discharge: the rotary valve and screw must handle a full day's dust. Dust left in the hopper bridges.
  7. Emissions: design for the stack limit and sampling point in your environmental permit from day one.

Buying a used dust collector

  • Check the casing for corrosion and holes, especially under the hopper.
  • Bags are normally replaced. Bent or rusty cages go too.
  • Test the pulse valves and diaphragms; make sure the controller comes with it.
  • Fan wheel balance, bearing noise, motor plate.
  • Rotary valve, screw and explosion panels in place.
  • Ask what airflow and dust it handled before. A unit from an iron foundry can be reviewed for aluminium only after an explosion-safety check.
  • Is ductwork included? On dismantling it usually goes to scrap, so price new ducting in.

FAQ

How often are bags replaced? In a correctly sized foundry baghouse, typically every 1 to 3 years. When differential pressure keeps rising and cleaning no longer brings it down, it is time.

Can one filter serve the whole foundry? In a small plant, possibly. Mixing furnace fume and blast dust in one unit is risky because of sparks and temperature. Most plants run separate filters for melting, sand and cleaning.

Why is suction weak after installation? Usually the hood is too far from the source, dust has settled in the ducts (it happens below about 18 m/s), the fan runs the wrong way, the bags are blinded or compressed air is short.

How much power does it use? Almost all of it is the fan. A 30,000 m³/h system typically has a 37-45 kW fan motor; a frequency inverter cuts consumption outside shift hours.

Related products and guides

What ZENES does

We look at the filter together with the extraction points. We measure each point on site, compare new filters from several makers on the same scope, and dismantle and reinstall used units. If you already have a filter, send us the nameplate and bag details and we will check whether it can handle the new line.